• Deutsch
  • English
  • Français

Wire Rope System 3030

This basic form is suitable when more wire rope density in the horizontal range is desired but if, due to a cramped area, three wires are inconvenient. The small rope sections ('bridges') on either side of the stem-guiding vertical cable offer the plants an additional grip. Please also refer to the guidelines in the section on climbing plants for the choice of a suitable construction style (charts at the bottom of each plant profile).

Order as a kit: parts list, information, and assembly tips

EasyLightMediumHeavyMassive
£26-45£64£85-155£145£213
 28-50 € 69.80 €  94-170 € 159.80 € 233.80 €
InfoInfoInfoInfoInfo
InstallationInstallationInstallationInstallationInstallation

 

The pre-assembled kits are suitable for all wall types with the exception of outer insulation, cladding, and thin-walled concrete elements. Alternatives can be put together in all cases.

 

Height x Breadth: max. 3.5 m x 6 m (4.5 m x 7.2 m for heavy/massive kits). Distance between the horizontal cables: approx. 15 - 50 cm; base approx. 0.5 to 1.2 m above the ground. With more cable and mounts, the cable system is expandable in all directions; then approx. every 1.5 m (1.8 m) inter-holders (mounts) are necessary. 

 

Installation: is carried out as indicated in the diagrams. Please also use the assembly tips above (click on a kit for more details). For easy kits, diagrams are not yet available. If you order climbing elements and ask specifically for information, you’ll receive these installation instructions immediately.

 

Vine Training/Shoot Guidance: See diagrams. Horizontal cordon (R 01). If foliage is desired in the vertical range, plant two plants in a planting pit for the separation of vertical and horizontal growing area, (particularly with large heights and/or breadths in which the branched shoot then is led in the vertical area with unleafy stem (R 02). Use two separate planting pits if vertical shoot is replanted later on (no picture). Also 2 parallel garlands from a shoot are possible; then the minimum distance of the ropes should be approx. 70 cm (R 03).

Shoot according to R 01, with summer cut
Greening with grapevine
Training in accordance with form R 01 before the winter cut
Trellis system for grapes
Vine according to R 01
Garage greening with grapevine
Medium Kit, vine in early growth phase, longer distance of the cables for R 03
Wire rope system for grapevine

Grapevine training on system 3030

R 01
R 02
R 03
Historical vine in accordance with R 03 on old climbing wires
Historical grapevine in Bornitz near Zeitz / Saxony-Anhalt
Medium Kit, (grape)vine
Wire rope system
Light / Medium / Heavy / Massive Kit