Construction Styles in Comparison

All climbing elements or cable systems at FassadenGrün are deliverable in different styles, as you can see below. You can buy pre-assembled kits, and you can adjust or add to these if necessary. Or, in the section on  "individual parts," put together your own personal kit with other wall mounts, parts, etc. If you need help at any time, please feel free to contact us.

Seilhalter für Dämmung s. unten im Größenvergleich, jeweils konfektioniert für 14 cm WDVS
Cable holder for insulation see below in size comparison, each ready-made for 14 cm ETICS

Similarities

All cable holders with support bodies have an M12 shaft and a seal to the wall. All cable brackets are made of A2 stainless steel, in exceptional cases also A4, and are designed for cable thicknesses of 4 mm (3 mm). All are bonded to the substrate with composite mortar and require a drill hole with a diameter of 16 mm. All have a medium to high load-bearing capacity for the insulation thicknesses assigned to them. A thermal break can be booked for the first four types (XP cable holders).

Criteria for the Choice of a Construction Style

For smaller and larger heights, strong and heavier loads, greening in public areas (where vandalism is an issue!), we have a system for you. Also with such climbers, where it is particularly indicated, heavy and solid climbing elements are preferable, as well as within semi-public areas, in yards, where children play football, etc., (where safety may be an issue). Otherwise, medium or simple kits almost always suffice, using only low loads with easy and light growing elements. Cable diameters of 2 or 3 mm are also less expensive, more flexible, and don't require holders big enough to fit 4 mm cable (as with massive and heavy constructions).

Montage

with ETICS

ETICS thickness

12 - 24 (30) cm

Wall distance

6 - 7 cm

⌀ Support body

125 mm

⌀ Cover disc

85 mm

Support body

Various

Thermal separation

optional

Price

+++

Montage

with ETICS

ETICS thickness

12 - 22) cm

Wall distance

9 - 10 cm

⌀ Support body

125 mm

⌀ Cover disc

85 mm

Support body

Various

Thermal separation

optional

Price

++++

Montage

later

ETICS thickness

12 - 18 cm

Wall distance

9 - 10 cm

⌀ Support body

90 mm

⌀ Cover disc

125 mm

Support body

Various

Thermal separation

optional

Price

++++

Montage

later

ETICS thickness

12 - 22 cm

Wall distance

9 - 10 cm

⌀ Support body

125 mm

⌀ Cover disc

150 mm

Support body

Various

Thermal separation

optional

Price

+++++

Montage

later

ETICS thickness

4 - 12 (14) cm

Wall distance

5 - 7 cm

⌀ Support body

60 mm

⌀ Cover disc

85 mm

Support body

Hardwood

Thermal separation

Not possible

Price

++

Support Bodies / Fixation Cylinders: Criteria

Supporting elements should be stable, rot-proof, only slightly heat-conducting and preferably also fireproof. FassadenGrün primarily uses hardwood here. However, if one of the above criteria is particularly important, other materials are also possible for an additional charge, see below.

Plastic support bodies

These can be booked as an additional service if there are high demands on rot resistance, e.g. when renovating old buildings (see above) or if organic materials are not desired for other reasons. Thick-walled pipe profiles made of PVC, POM or PU are used, which have a compressive strength similar to solid wood. Supporting blocs made of PUR foam or other inferior materials will deform in time and shouldn't be used.

Supporting blocs of cellular glass

Foam glass supports used to be the standard for all XP mounts from Fassadengrün. From 09/2024, foam glass can be booked as a special service if particularly high demands are placed on the insulating effect. This is possible if an energy performance certificate has been drawn up for a building in order to demonstrate a low, passive or zero energy standard and to obtain a corresponding KfW subsidy. If retrofitting a large number of XP brackets would significantly reduce the insulation values of the façade, foam glass brackets can be used. This applies in particular to the large-area supports for XP 12XX5 and XP 12XX9. We use mainly blocs made of cellular glass that have a resistance of 2,500 Mpa, way more than the common PUR foam and its 500 Mpa or similar insulating foams. Even under high loads the cellular glass remains undeformed. Nevertheless, cellular glass has the lowest pressure values of all our supporting elements, which is why only 3 mm ropes may be used here.

Foam glass is "non-combustible" and therefore also suitable for high-rise buildings - please contact us if necessary.

Montage

with ETICS

ETICS thickness

12 - 24 (30) cm

Wall distance

6 - 7 cm

⌀ Support body

125 mm

⌀ Cover disc

85 mm

Support body

Foam glass

Thermal separation

optional

Price

+++

Montage

with ETICS

ETICS thickness

12 - 22) cm

Wall distance

9 - 10 cm

⌀ Support body

125 mm

⌀ Cover disc

85 mm

Support body

Foam glass

Thermal separation

optional

Price

++++

Montage

later

ETICS thickness

12 - 18 cm

Wall distance

9 - 10 cm

⌀ Support body

90 mm

⌀ Cover disc

125 mm

Support body

Foam glass

Thermal separation

optional

Price

++++

Montage

later

ETICS thickness

12 - 22 cm

Wall distance

9 - 10 cm

⌀ Support body

125 mm

⌀ Cover disc

150 mm

Support body

Foam glass

Thermal separation

optional

Price

+++++

Montage

later

ETICS thickness

4 - 12 (14) cm

Wall distance

5 - 7 cm

⌀ Support body

60 mm

⌀ Cover disc

85 mm

Support body

Hardwood

Thermal separation

Not possible

Price

++